MASTER AUTOM GROUP -- WINDSHIELD WASHER CONCENTRATE -- 7930-00N089048
===================== Product Identification ===================== Product ID:WINDSHIELD WASHER CONCENTRATE MSDS Date:04/15/1987 FSC:7930 NIIN:00N089048 Status Code:A === Responsible Party === Company Name:MASTER AUTOM GROUP Box:381900 City:GERMANTOWN State:TN ZIP:38183-1900 Country:US Info Phone Num:901-757-5700 Emergency Phone Num:800-255-3924 CAGE:MAAUT === Contractor Identification === Company Name:MASTER AUTOM GROUP Address:1900 EXETER ROAD Box:381900 City:GERMANTOWN State:TN ZIP:38138-1190 Country:US Phone:901-755-6677 CAGE:MAAUT ============= Composition/Information on Ingredients ============= Ingred Name:METHYL ALCOHOL (SARA 313) (CERCLA) CAS:67-56-1 RTECS #:PC1400000 Fraction by Wt: >95% OSHA PEL:200 PPM, S ACGIH TLV:200 PPM;250 STEL, S EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:SUPDAT:LOCATIONS DIST FROM MATL HNDLG POINT. NEVER USE WELDING/CUTTING TORCH ON/NEAR DRUM (EVEN EMPTY) BECAUSE (ING 3) RTECS #:9999999ZZ Ingred Name:ING 2:PROD (EVEN JUST RESIDUE) CAN IGNITE EXPLOSIVELY. ALL 5 GAL PAILS & LARGER METAL CNTNRS INCL TANK CARS & (ING 4) RTECS #:9999999ZZ Ingred Name:ING 3:TANK TRUCKS SHOULD BE GROUNDED &/OR BONDED WHEN MATERIAL IS TRANSFERRED. RTECS #:9999999ZZ Ingred Name:SPILL PROC:ELEC SPKS). PERS NOT WEARING PROT EQUIP SHOULD BE EXCLUDED FROM AREA OF SPILL UNTIL CLEAN-UP HAS BEEN (ING 6) RTECS #:9999999ZZ Ingred Name:ING 5:COMPLETED. STOP SPILL AT SOURCE, DIKE AREA OF SPILL TO PVNT SPREADING, PUMP LIQ TO SALVAGE TANK. REMAINING (ING 7) RTECS #:9999999ZZ Ingred Name:ING 6:LIQ MAY BE TAKEN UP ON SAND, CLAY, EARTH, FLOOR ABSORB/OTHER ABSORB MATL & SHOVELED INTO CNTNRS. PREVENT (ING 8) RTECS #:9999999ZZ Ingred Name:ING 7:RUN-OFF TO SEWERS, STREAMS/OTHER BODIES OF WATER. IF RUN-OFF OCCURS, NOTIFY PROPER AUTHS AS REQD, THAT A (ING 9) RTECS #:9999999ZZ Ingred Name:ING 8:SPILL HAS OCCURRED. RTECS #:9999999ZZ Ingred Name:OTHER PREC:RESIDUES (VAP, LIQ &/OR SOLID), ALL HAZ PRECS GIVEN IN MSDS MUST BE OBSERVED. CNTNRS SHOULD BE (ING 11) RTECS #:9999999ZZ Ingred Name:ING 10:EITHER RECONDITIONED BY CERTIFIED FIRMS/PROPERLY DISPOSED OF BY APPRVD FIRMS. DISP OF CNTNRS SHOULD BE (ING 12) RTECS #:9999999ZZ Ingred Name:ING 11:I/A/W APPLIC LAWS & REGS. "EMPTY" DRUMS SHOULD NOT BE GIVEN TO INDIVIDUALS. SERIOUS ACCIDENTS HAVE (ING 13) RTECS #:9999999ZZ Ingred Name:ING 12:RESULTED FROM MISUSE OF "EMPTIED" CNTNRS (DRUMS, PAILS, ETC). RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:EYES:CAN CAUSE SEV IRRIT, REDNESS, TEARING, BLURRED VISION. SKIN:PRLNG/RPTD CONT CAN CAUSE MOD IRRIT, DEFAT, DERM. INHAL:EXCESSIVE INHAL OF VAPS CAN CAUSE NASAL & RESP IRRIT, DIZZ, WEAK, FATG, N AUS, HDCH, POSS UNCON & EVEN ASPHY. INGEST:CAN CAUSE GI IRRIT, NAUS, VOMIT, DIARR, BLINDNESS & DEATH. (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:CHRONIC:OVEREXP TO THIS MATL (OR ITS COMPONENTS) HAS APPARENTLY BEEN FOUND TO CAUSE FOLLOWING EFTS IN LAB ANIMALS: LIVER ABNORMS, KIDNEY DMG, EYE DMG, LUNG DMG, SPLEEN DMG, BRAIN DMG, NERV SY S DMG. OVEREXP TO THIS MATL (OR ITS COMPONENTS) HAS BEEN SUGGESTED AS CAUSE OF FOLLOWING EFTS IN HUMANS: EYE DMG. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:SKIN:THORO WASH EXPOS AREA W/SOAP & WATER. REMOVE CONTAM CLTHG. LAUNDER CONTAM CLTHG BEFORE RE-USE. EYES:FLUSH W/LG AMTS OF WATER FOR AT LST 15 MINS, LIFTING UPPER & LOWER LIDS OCCAS, GET MED ATTN. IN GEST:IMMED DRINK 2 GLASSES OF WATER & INDUCE VOMIT BY EITHER GIVING IPECAC SYRUP/BY PLACING FINGER AT BACK OF THROAT. NEVER GIVE ANYTHING BY MOUTH TO UNCON PERS. GET MED ATTN IMMED. INHAL: (SUPP DATA) ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:54.0F,12.2C Lower Limits:4% Extinguishing Media:WATER FOG, CARBON DIOXIDE OR DRY CHEMICAL. Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY TRAVEL ALONG GROUND/MAY BE MOVED BY VENT & IGNITED BY PILOT LIGHTS, OTHER FLAMES, SPKS, HEATERS, SMOKING, ELEC MOTORS, STATIC (SUPP DATA) ================== Accidental Release Measures ================== Spill Release Procedures:SM SPILL:ELIM ALL SOURCES OF IGNIT SUCH AS FLARES, FLAMES (INCL PILOT LIGHTS) & ELEC SPKS. ABSORB LIQ ON PAPER, VERMICULITE, FLOOR ABSORB/OTHER ABSORB MATL & TRANSFER TO HOOD. LG SPILL:ELIM ALL IGNIT SOURCES (FLARES, FLAMES INCL PILOT LIGHTS, (ING 5) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:CONTAINS METHANOL. CANNOT BE MADE NONPOISONOUS. ALUMINUM MAY FORM OXIDE SCALE ON PROLONGED EXPOSURE TO METHANOL. Other Precautions:SKIN ABSORPTION MAY POTNTLY CONTRIBUTE TO OVERALL EXPOS TO THIS MATL. APPROP MEASURES SHOULD BE TAKEN TO PVNT ABSORPTION SO THAT TLV IS NOT INVALIDATED. CNTNRS OF THIS MATL MAY BE HAZ WHEN EMPTIED. SI NCE EMPTIED CNTNRS RETAIN PROD (ING 10) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF TLV OF PROD/ANY COMPONENT IS EXCEEDED, A NIOSH APPRVD AIR SUPPLIED RESP IS ADVISED IN ABSENCE OF PROPER ENVIRON CONTROL. OSHA REGS ALSO PERMIT OTHER NIOSH APPRVD RESPS UNDER SPECIFIED CNDTNS. (SEE YOUR SFTY EQUIP SUPPLIER). (SUPP DATA) Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL &/OR LOCAL EXHAUST) VENTILATION TO MAINTAIN EXPOSURE BELOW TLV(S). Protective Gloves:RESISTANT GLOVES (NEOPRENE). Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS . Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE SHOWER . TO PVNT RPTD/PRLNG SKIN CONT, WEAR IMPERVIOUS CLOTHING & BOOTS. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health FIRST AID PROC:REMOVE INDIVIDUAL TO FRESH AIR. IF BRTHG IS DFCLT, ADMIN OXYG. IF BRTHG HAS STOPPED GIVE ARTF RESP. KEEP PERS WARM, QUIET & GET MED ATTN. WASTE DISP METH:STATE & FED REGS. RESP PROT:ENG INEERING/ADMIN CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXPOS. EXPLO HAZ:DISCHARGE/OTHER IGNIT SOURCES AT (ING 2) ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:147F,64C Vapor Pres:97 @ 20C Vapor Density:1.1 Spec Gravity:0.793 Evaporation Rate & Reference:6.91 (N-BUTYL ACETATE=1) Appearance and Odor:BLUE LIQUID; HOMOG SOLN. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES AVOID CONTACT W/STRONG OXIDIZING AGENTS. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS, CARBON DIOXIDE & CARBON MONOXIDE, VARIOUS HYDROCARBONS, ETC. ==================== Disposal Considerations ==================== Waste Disposal Methods:SM SPILL:ALLOW VOLAT PORTION TO EVAP IN HOOD. ALLOW SUFFICIENT TIME FOR VAPS TO COMPLETELY CLEAR HOOD DUCT WORK. DISP OF REMAINING MATL I/A/W APPLIC REGS. LG SPILL:DESTROY BY LIQ INCIN. CONTAM ABSORB MAY BE DEPOSITED IN LANDFILL I/A/W LOC,(SUPDAT) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.